<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis</journal-id><journal-title-group><journal-title xml:lang="en">Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis</journal-title><trans-title-group xml:lang="kk"><trans-title>Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis</trans-title></trans-title-group><trans-title-group xml:lang="pt"><trans-title>Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis</trans-title></trans-title-group><trans-title-group xml:lang="ru"><trans-title>Университетская стоматология и челюстно-лицевая хирургия</trans-title></trans-title-group><trans-title-group xml:lang="zh"><trans-title>Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis</trans-title></trans-title-group></journal-title-group><issn publication-format="electronic">3034-297X</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">697917</article-id><article-id pub-id-type="doi">10.17816/uds697917</article-id><article-id pub-id-type="edn">QZJZSU</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Scientific research</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Научные исследования</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Finite element analysis of the effects of orthodontic force on a microimplant and maxillary structures: A case-control study</article-title><trans-title-group xml:lang="ru"><trans-title>Изучение методом конечных элементов влияния ортодонтической силы на микроимплантат и структуры верхней челюсти: исследование случай — контроль</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-3467-4479</contrib-id><contrib-id contrib-id-type="spin">4556-5177</contrib-id><name-alternatives><name xml:lang="en"><surname>Fadeev</surname><given-names>Roman A.</given-names></name><name xml:lang="ru"><surname>Фадеев</surname><given-names>Роман Александрович</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>MD, Dr. Sci. (Medicine), Professor</p></bio><bio xml:lang="ru"><p>д-р мед. наук, профессор</p></bio><email>sobol.rf@yandex.ru</email><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0000-0602-2508</contrib-id><contrib-id contrib-id-type="spin">5631-2274</contrib-id><name-alternatives><name xml:lang="en"><surname>Shevchenko</surname><given-names>Irina K.</given-names></name><name xml:lang="ru"><surname>Шевченко</surname><given-names>Ирина Константиновна</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><email>irinash88@yandex.ru</email><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">North-Western State Medical University named after. I.I. Mechnikov</institution></aff><aff><institution xml:lang="ru">Северо-Западный государственный медицинский университет им. И.И. Мечникова</institution></aff><aff><institution xml:lang="kk"></institution></aff><aff><institution xml:lang="pt"></institution></aff><aff><institution xml:lang="zh"></institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en">North-Western State Medical University named after. I.I. Mechnikov</institution></aff><aff><institution xml:lang="ru">Северо-Западный государственный медицинский университет им. И.И. Мечникова</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2026-02-27" publication-format="electronic"><day>27</day><month>02</month><year>2026</year></pub-date><volume>3</volume><issue>4</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>150</fpage><lpage>155</lpage><history><date date-type="received" iso-8601-date="2025-12-05"><day>05</day><month>12</month><year>2025</year></date><date date-type="accepted" iso-8601-date="2025-12-22"><day>22</day><month>12</month><year>2025</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2025, Eco-Vector</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2025, Эко-вектор</copyright-statement><copyright-year>2025</copyright-year><copyright-holder xml:lang="en">Eco-Vector</copyright-holder><copyright-holder xml:lang="ru">Эко-вектор</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://creativecommons.org/licenses/by-nc-nd/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://stomuniver.ru/unistom/article/view/697917">https://stomuniver.ru/unistom/article/view/697917</self-uri><abstract xml:lang="en"><p><bold>BACKGROUND:</bold> Orthodontic microimplants placed in the infrazygomatic region are increasingly used in clinical practice. However, no systematic studies have been identified that comprehensively characterize the anatomy of this region and the magnitude of forces acting on a microimplant placed in the infrazygomatic region.</p> <p><bold>AIM:</bold> To evaluate the effects of orthodontic force applied to a microimplant and the surrounding maxillary structures using finite element analysis.</p> <p><bold>METHODS:</bold> A digital model of the maxilla was constructed for a patient undergoing orthodontic treatment with a fixed appliance system and a microimplant placed in the infrazygomatic region. Finite element analysis was performed to assess the influence of orthodontic force on the microimplant and adjacent maxillary structures (including the movable oral mucosa, the cortical plate, and the cancellous bone of the alveolar process).</p> <p><bold>RESULTS:</bold> Under applied loading, the model demonstrated changes in physical parameters. The total deformation of the microimplant was 0.0002 mm, which may be interpreted as minimal and not affecting its stability. Equivalent stress in the model was concentrated in the cortical plate of the maxilla, with the limit reaching 0.021 MPa. Due to the high density of the cortical bone, equivalent stress values in the cancellous bone were several times lower.</p> <p><bold>CONCLUSION:</bold> The deformation processes were localized and remained within physiological limits, confirming appropriate load distribution between the implant and surrounding tissues.</p></abstract><trans-abstract xml:lang="ru"><p><bold>Обоснование.</bold> Широкое клиническое применение получают ортодонтические микроимплантаты, установленные в подскуловую область. Нами не обнаружено систематизированных исследований, характеризующих анатомию области и величину сил, воздействующих на микроимплантат в подскуловой области.</p> <p><bold>Цель исследования.</bold> Изучить влияние ортодонтической силы, воздействующей на микроимплантат и структуры верхней челюсти, с помощью метода конечных элементов.</p> <p><bold>Методы.</bold> Построена цифровая модель верхней челюсти пациента, проходящего ортодонтическое лечение с применением брекет-системы и микроимплантата, установленного в подскуловую область. С помощью метода конечных элементов проанализировано влияние ортодонтической силы, воздействующей на микроимплантат и структуры верхней челюсти (подвижную слизистую оболочку полости рта, компактную пластинку и губчатую ткань альвеолярного отростка).</p> <p><bold>Результаты.</bold> Под воздействием нагрузки модель демонстрировала изменения физических характеристик. Установлено, что общие деформационные изменения микроимплантата составили 0,0002 мм, что можно быть интерпретировано как минимальные значения, не оказывающие влияния на его стабильность. Эквивалентное напряжение в модели концентрировалось в области компактной пластинки верхней челюсти, при этом предел значений составил 0,021 МПа. За счёт высокой плотности компактной пластинки в губчатой ткани эквивалентное напряжение уменьшалось в несколько раз.</p> <p><bold>Заключение.</bold> Деформационные процессы носят локализованный характер и находятся в пределах физиологической нормы, что подтверждает корректность распределения нагрузки между имплантатом и окружающими тканями.</p></trans-abstract><kwd-group xml:lang="en"><kwd>orthodontic microimplant</kwd><kwd>finite element analysis</kwd><kwd>orthodontic treatment</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>ортодонтический микроимплантат</kwd><kwd>метод конечных элементов</kwd><kwd>ортодонтическое лечение</kwd></kwd-group><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Shevchenko IK, Fadeev RA. Use of orthodontic miniscrews to correct the distal malocclusion. Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis. 2024;2(2):57–65. doi: 10.17816/uds631887 EDN: YELYRH</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Du B, Zhu J, Li L, et al. Bone depth and thickness of different infrazygomatic crest miniscrew insertion paths between the first and second maxillary molars for distal tooth movement: A 3-dimensional assessment. Am J Orthod Dentofacial Orthop. 2021;160(1):113–123. doi: 10.1016/j.ajodo.2020.03.036 EDN: GAOYZO</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Murugesan A, Sivakumar A. Comparison of bone thickness in infrazygomatic crest area at various miniscrew insertion angles in Dravidian population — A cone beam computed tomography study. Int Orthod. 2020;18(1):105–114. doi: 10.1016/j.ortho.2019.12.001 EDN: FLVUJP</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Carano A, Velo S, Incorvati C, Poggio P. Clinical applications of the Mini-Screw-Anchorage-System (M.A.S.) in the maxillary alveolar bone. Prog Orthod. 2004;5(2):212–235.</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Jia X, Chen X, Huang X. Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region. Am J Orthod Dentofacial Orthop. 2018;153(5):656–661. doi: 10.1016/j.ajodo.2017.08.021</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Rogozhnikov GI, Konyukhova SG, Nyashin YuI, Chernopazov SA. The influence of the elastic modulus of spongy and cortical bone on the stress state in the area of a plate implant under occlusal load. Russian journal of biomechanics. 2004;8(1):58–60. (In Russ.) EDN: JWSHCL</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Perelmuter MN. Analysis of stress-strain state of dental implants by the boundary integral equations method. PNRPU mechanics bulletin. 2018;(2):83–95. doi: 10.15593/perm.mech/2018.2.08 EDN: XUGGCL</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>Perelmuter MN. Stress concentration in bone tissues and screw dental implants. Russian journal of biomechanics. 2023;(2):18–29. doi: 10.15593/RZhBiomech/2023.2.02 EDN: CXBTIB</mixed-citation></ref></ref-list></back></article>
